UL1278 UL507 Probe For Film Coated Wire 19.1 Mm To Verify Accessibility Of Live Parts

Guangzhou HongCe Equipment Co., Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now

UL1278 UL507 Probe For Film Coated Wire 19.1 Mm To Verify Accessibility Of Live Parts

  • 1
  • 2
  • 3

Brand Name : HongCe

Model Number : HT-U03

Certification : Calibration Certificate (cost additional)

Place of Origin : China

MOQ : 1 set

Price : Negotiatable

Payment Terms : T/T

Supply Ability : 100 set per month

Delivery Time : 3 Days

Packaging Details : Aluminum Box

Product name : Probe for Film-Coated Wire

Warranty : 1 Year

Standard : UL398, UL507, UL1278 and etc.

Test sample : Transformers and inductors

Feature : Nylon handle + probe

Material : Stainless steel

Length : 101.6mm

Diameter : 19.1mm

Contact Now

UL1278 UL507 Probe for Film-coated Wire 19.1 mm to Verify Accessibility of Live Parts​

Description in UL1278 Clause 8.1~8.5:

8 Accessibility of Live Parts

8.1 An electrical part of a heater shall be so located or enclosed that protection against unintentional contact with uninsulated live parts will be provided, except that this requirement does not apply to a visibly glowing open-wire element and the connections immediately adjacent to the element. See 3.1 , 8.2, 32.7 and 32.1 4. Insulated motor brush caps do not require additional enclosures.

8.2 The requirement in 8.1 does not apply to the sheath of an isolated metal-clad element in a heater having provision for grounding the enclosure, although such a sheath is considered to be a bare live part when spacings are being measured.

8.3 In determining if an opening in an enclosure is acceptable, consideration is to be given to:

a) The proximity of uninsulated live parts (as determined by applying 8.1 , 8.2, 8.4, 8.5, and 8.1 5 and

b) The possibility of the emission of burning insulation, molten metal, and similar materials through the opening (as determined by applying 7.3 – 7.6.) Test Finger Probe

8.4 To reduce the likelihood of unintentional contact that may involve a risk of electric shock from an uninsulated live part or film-coated wire, an opening in an enclosure shall comply with either (a) or (b).

a) For an opening that has a minor dimension (see 8.8) less than 1 inch (25.4 mm), such a part or wire shall not be contacted by the probe illustrated in Figure 8.3.

b) For an opening that has a minor dimension of 1 inch or more, such a part or wire shall be spaced from the opening as specified in Table 8.1 . Test Finger Probe

Exception: An integral enclosure of a motor need not comply with these requirements if it complies with the requirements in 8.5.

8.5 With respect to a part or wire as mentioned in 8.4, in an integral enclosure of a motor as mentioned in the exception to 8.4:

a) An opening that has a minor dimension (see 8.8) less than 3/4 inch (1 9.1 mm) is acceptable if:

1 ) Film-coated wire cannot be contacted by the probe illustrated in Figure 8.2;

2) In a directly accessible motor (see 8.9), an uninsulated live part cannot be contacted by the probe illustrated in Figure 8.4; or

3) In an indirectly accessible motor (see 8.9), an uninsulated live part cannot be contacted by the probe illustrated in Figure 8.1 .

b) An opening that has a minor dimension of 3/4 inch (1 5.1 mm) or more is acceptable if a part or wire is spaced from the opening as specified in Table 8.1 . Test Finger Probe

UL1278 UL507 Probe For Film Coated Wire 19.1 Mm To Verify Accessibility Of Live Parts

Standard:UL398 Fig 8.2(PA170B),UL507(PA170D),UL749 Fig 2,UL982 Fig 58.6 and UL1278 Fig 8.2(PA140A).

Application:It is used for the testing of coating lines of the enamel (i.e., transformers and inductors).

Test sample:Transformers and inductors.

Feature:Nylon handle + probe, it is manufactured according to the standard figure. Test Finger Probe

Parameters:

Length 4’’ (101.6mm)
RAD. 1/4’’(6.4mm)
DIA. 1 1/2’’(12.7mm)
DIA. 2 3/4’’(19.1mm)

UL1278 UL507 Probe For Film Coated Wire 19.1 Mm To Verify Accessibility Of Live Parts

Picture for reference:

UL1278 UL507 Probe For Film Coated Wire 19.1 Mm To Verify Accessibility Of Live Parts


Product Tags:

UL 1278 Test Finger Probe

      

Film Coated Wire Test Finger Probe

      

101.6mm Length Test Finger Probe

      
Quality UL1278 UL507 Probe For Film Coated Wire 19.1 Mm To Verify Accessibility Of Live Parts for sale

UL1278 UL507 Probe For Film Coated Wire 19.1 Mm To Verify Accessibility Of Live Parts Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Guangzhou HongCe Equipment Co., Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)